...

MS100Custom grid humidification system

Build humidity distribution around the shape of your facility. The MS100 is engineered for production lines, large spaces, and layouts where several delivery points must work together.

MS100 custom humidification system on a blue equipment frame
Custom grid humidificationFull-size photo ↗

What determines an MS100 grid

A custom grid is selected from the facility layout and humidity load. A floor-area number alone cannot determine the number of delivery points or how to group them into zones.

Design inputWhat it determines
Room dimensions and obstructionsGrid geometry, mounting, and service access
Supply air, exhaust, and open doorsMoisture load and distribution
Temperature and target RH by areaZone boundaries and control strategy
Available air, water, and powerUtility sizing and connection locations

Grid capacity, equipment quantities, and utility requirements are established for the specific project.

From facility drawing to grid layout

Map where humidity matters

Mark the processes, stored materials, and work areas that need humidity control. Identify aisles, cranes, racking, high ceilings, and obstructions that limit mounting positions.

Separate unlike loads

A loading door, oven exhaust, or outdoor-air supply can create a local drying load. Review those areas separately before deciding which delivery points can share a sensor and control zone.

Coordinate installation

Engineering can review mounting, the routing of supply tubing, and access to sensors and controls. Share planned expansion areas so future phases can be considered in the layout.

MS100 application questions

When is a custom grid preferable to individual ES100 units?

Consider an MS100 when the geometry, required distribution, or number of control zones calls for a coordinated grid. For an individual room that can be served from a few wall locations, start with the ES100.

Is there a standard coverage area?

Coverage depends on ceiling height, ventilation, temperature, setpoint, and process losses. Two facilities with the same footprint can require different equipment and layouts.

What controls and options can be specified?

A project may include CPLC control, S Series RH sensors, PB valve control, tubing and fittings, ZeroTDS water treatment, and a building-controls interface. The proposal identifies the selected components.

What should the initial drawing show?

A dimensioned floor plan is ideal. Mark the ceiling height, process equipment, doors, air outlets and exhausts, and preferred utility locations. A rough sketch is enough to start the conversation.

Start your custom grid layout

Send a dimensioned plan or describe the space in the inquiry. Include ceiling height, target RH and temperature by zone, major exhausts or doors, and any mounting or access restrictions.

Request a grid layout  →