HVAC infrastructure
ASHRAE Psychrometrics

Enthalpy Calculator

Calculate the total energy content of moist air — specific enthalpy, humidity ratio, specific volume, and vapor pressure. Enter dry-bulb temperature plus relative humidity, wet-bulb, or dew point.

3 Modes
RH / Wet-Bulb / Dew Point
60%
Less Energy vs. Steam
SI + IP
Metric & Imperial

Enter Your Values

Unit System
°C
%

Your Results

Enter dry-bulb temperature and one
humidity value to see all properties.

Understanding Enthalpy

The Total Energy Your Air Carries

Enthalpy is the single number HVAC engineers use to size systems and compare humidification methods. It tells you how much heat the air holds — and how much your humidifier is adding to it.

Specific enthalpy is the total energy content of moist air per kilogram of dry air, combining the sensible heat of the air with the latent heat of its water vapor. Engineers use it to size air handlers, calculate cooling and heating loads, and — critically — to compare the energy cost of different humidification methods.

How much a humidifier changes enthalpy depends on the process. Steam adds moisture and heat, spiking enthalpy. Adiabatic humidification like Smart Fog's dry fog adds moisture while absorbing heat, so net enthalpy barely moves.

Specific Enthalpy of Moist Airh = 1.006·T + W·(2501 + 1.86·T) [kJ/kg]

T = dry-bulb temp (°C)
W = humidity ratio (kg water / kg dry air)
1.006 = specific heat of dry air
2501 = latent heat of vaporization at 0°C

This calculator derives every psychrometric property from dry-bulb temperature plus your choice of relative humidity, wet-bulb temperature, or dew point — the three ways moisture is measured in the field — at standard sea-level pressure (101.325 kPa).

Why Engineers Need This

  • Size air handling units and cooling coils accurately
  • Calculate heating and cooling loads for humidified spaces
  • Compare energy cost of steam vs. adiabatic humidification
  • Validate psychrometric chart readings to full precision

Isothermal vs. Adiabatic

Steam (isothermal): adds moisture at constant temperature, raising enthalpy sharply — your cooling system pays for it. Adiabatic (dry fog): evaporates water, absorbing heat as it humidifies, so net enthalpy change is near zero.

Smart Fog energy-efficient humidification
The Smart Fog Difference

Humidify Without Inflating Your Energy Bill

Every humidifier changes your air's enthalpy — the question is how much. Steam injects high-energy vapor that your cooling system then has to remove. Smart Fog's adiabatic dry fog adds moisture by evaporation, absorbing heat instead of adding it, so net enthalpy barely moves.

Near-Zero Enthalpy Gain

Evaporation absorbs heat as it humidifies — your cooling system isn't fighting the humidifier.

Up to 60% Less Energy

No boiler, no steam generation — dramatically lower operating cost than isothermal systems.

Smaller HVAC Spec

Because the humidifier adds no heat load, you can specify smaller, cheaper cooling capacity.

Precision Humidity By Facility

Where Enthalpy Control Pays Off

Energy-intensive, humidity-critical environments where adiabatic humidification cuts load and cost.

FAQ

Common Questions

Everything you need to know about moist air enthalpy and humidification energy.

Still have questions? Ask an expert
Enthalpy is the total heat energy in moist air per kilogram of dry air, combining sensible heat (from temperature) and latent heat (from moisture). Engineers use it to size cooling coils, calculate heating and cooling loads, and evaluate the energy cost of humidification. Without accurate enthalpy, HVAC systems end up oversized and wasteful or undersized and unable to hold conditions.
Steam humidification adds roughly 2,676 kJ of energy for every kilogram of steam, raising enthalpy sharply — your cooling system must remove that heat. Adiabatic humidification like Smart Fog's dry fog evaporates water droplets that absorb heat from the air, so sensible temperature drops as humidity rises and net enthalpy barely changes. That's why adiabatic systems use 50–90% less total energy than steam.
Humidity ratio measures only the mass of water vapor per mass of dry air (g/kg or grains/lb). Enthalpy includes both that moisture energy and the sensible heat of the air itself. Two air samples can share a humidity ratio but have different enthalpies at different temperatures — which is why enthalpy is the standard for load calculations.
Yes. The enthalpy, humidity ratio, and specific volume values here are the inputs for air handler sizing, coil selection, and humidification load estimation. The enthalpy difference between two air states, multiplied by airflow, gives total load in kW or BTU/hr. For a full facility analysis with Smart Fog integration, our engineers provide custom psychrometric studies.
Standard sea-level pressure of 101.325 kPa (14.696 psia). At higher elevations, lower pressure changes humidity ratio and specific volume. For facilities above about 1,000 m (3,300 ft), contact Smart Fog for altitude-adjusted calculations.