Industrial Humidifiers & Humidification Systems
Compare industrial humidifier types and choose a delivery method for your building. Smart Fog designs U.S.-made in-room, in-duct, mobile and custom systems for commercial and industrial applications.
Get industrial humidifier sizing and pricing
Tell us the process, the size of the space and the humidity you need to hold. A Smart Fog engineer replies with sizing and a quote. Prefer to talk? Call 1-800-921-5230.
Industrial humidifier models and specifications
An industrial size humidifier system is built from the units below. Plants and production floors usually take wall-mounted ES100 units or an MS100 grid. An industrial room humidifier fed by its own air handler takes the TS100, and the ES100M is a portable industrial humidifier for one zone.
| Model | How it is installed | Humidity output | Compressed air | Water supply | Controls |
|---|---|---|---|---|---|
| ES100 | Wall-mounted, fogs directly into the space | 0–25 lb/hr (0–11 L/h), about 0.4 kW at maximum output | 4 CFM at 100 psi | 10 psi | CPLC controller, optional Modbus or BACnet |
| MS100 | Custom nozzle grid for large spaces | Sized to the project, up to 10,000 sq ft per system | Sized to the project | Sized to the project | Zoned control, optional Modbus or BACnet |
| TS100 | Inside new or existing ductwork | 0–25 lb/hr (0–11 L/h), about 0.4 kW at maximum output | 4 CFM at 100 psi | 10 psi | CPLC controller, optional Modbus or BACnet |
| ES100M | Portable unit on a wheeled base | Up to about 13 lb/hr (6 L/h) | 2 CFM at 100 psi | 10 psi | RH sensor and controller |
Smart Fog supplies industrial humidifiers to plants across the United States and Canada. For offices and commercial buildings, see commercial humidification systems.
Which industrial humidification system fits your facility?
Choose the delivery method first, then size its evaporation capacity. Industrial humidifiers protect processes such as printing, electronics assembly, woodworking and cold storage by adding moisture when ventilation or heating leaves the air too dry. Offices and commercial buildings often use central HVAC distribution, while factories may need independent humidity control at individual production lines.
| Facility condition | System to consider | Check before specifying |
|---|---|---|
| Separate production areas or shifts | ES100 direct-space humidifier | Air circulation at product height, room zoning, mounting positions and distance to nearby surfaces. |
| Dedicated air handler serving a zone | TS100 in-duct humidifier | Minimum airflow, duct cross section, straight-run length, sensor position and downstream humidity limit. |
| Temporary or changing demand | ES100M mobile system | Utilities at each position, safe placement and how humidity reaches the work area. |
| Large or unusual airstream | MS100 custom grid | Airflow profile, access for maintenance, utility demand and the intended control sequence. |
Compare industrial humidifier technologies
A steam humidifier boils water or receives steam from a central source. Steam adds moisture with little change in air temperature at the point of absorption. Compare heating energy, distribution losses, cylinder or boiler maintenance and condensate handling.
Water evaporates into the airstream and draws sensible heat from the air. Smart Fog distributes Self-Evaporating Droplets directly into a room or duct. Compare available heat, compressed-air power, water treatment and evaporation distance.
Ultrasonic systems use vibrating transducers to produce fine droplets. A wetted-media system passes air across a wet surface. Evaluate the water specification and cleaning requirements of each system, plus pressure loss for media installed in the air handling system.
How much water must the industrial humidifier deliver?
Determine how much dry replacement air enters the building and how much moisture that air lacks at the indoor target. Use actual airflow, entering temperature and RH, target conditions and site pressure. Account for internal moisture gains, process losses and any justified design allowance. Calculate the load in lb/h or kg/h before selecting a model or a nozzle count.
Identical floor area, different humidifier size. If one production room exhausts twice as much air as another, it can need twice the ventilation humidification capacity at the same entering and target conditions. Compare exhaust schedules and door openings as well as room volume. Calculate the humidification load.
What belongs in a comparable supplier quote?
Specify output at the design conditions, minimum controllable capacity, number of zones, temperature and RH control bands, water quality, utility loads, required drain and service access. Ask how much of the injected water is expected to evaporate in the available space at minimum airflow. Quantify installed and operating costs at the same production schedule.
For an existing plant, compare actual electrical and heating duties across the full system boundary. Include compressed air and water treatment for an atomizing system, and steam generation or purchased-steam costs for a steam system. Document sensor checks, filtration and maintenance intervals for the selected equipment.
Where is the system most useful?
Start with the product or operating loss you can measure. A print plant may track paper curl and feeder stoppages. A grower may track moisture distribution at racks; an electronics plant may track seasonal humidity excursions alongside its ESD program. Verify performance at representative points rather than at a single humidifier outlet.
Printing humidification · Mushroom growing rooms · Humidity for electronics and ESD · Smart Fog technology
How can you compare two humidification quotes fairly?
Give both suppliers the same outdoor air quantity, entering condition, target humidity, and production schedule. Ask each to state delivered capacity at that condition, utility requirements at part load, water treatment, and annual service assumptions. That makes differences in equipment size and operating cost easier to explain. Compare the ES100 and TS100 by installation →
How do industrial humidification systems maintain consistent humidity?
A humidistat or humidity sensor measures relative humidity and the controller adjusts output toward the process setpoint. An industrial humidification system sized for a dry winter shift should also be able to turn down when exhaust stops or internal moisture gains rise. Otherwise an average room reading can look acceptable while material near the discharge gets wet.
Smart Fog reports approximately ±1–2 percentage points of RH control in suitable installations. Agree on the setpoint, the acceptable range, the sensor locations and response time. In a printing plant, qualify conditions where stock is conditioned and at the press. In electronics, check representative handling stations as well as the return. For moisture-sensitive products, record product condition alongside air humidity.
How does an adiabatic humidifier compare with steam?
Isothermal humidification adds steam from a boiler or electric generator. Adiabatic humidification evaporates liquid water into the air without supplying the latent heat from a steam generator. The air provides that heat and cools as its humidity rises. This can reduce purchased humidification energy when the process already has excess heat. In winter a system may need extra heat to maintain its final air temperature. Include both effects in an energy comparison.
What causes maintenance costs to vary?
Inspect the complete humidification system: water treatment, distribution, air supply, nozzles or transducers, sensors and controls. Hard water can leave mineral deposits. Water storage, drain design and cleaning access vary by technology. Compare each supplier’s water requirements and maintenance schedule at the anticipated hours of operation. Smart Fog’s stationary nozzle has no moving parts, while upstream filters and utilities still require service.
How do humidity and operating cost vary by industry?
In printing, rapid moisture loss can curl paper and interfere with feeding. In woodworking, changes in equilibrium moisture content can affect dimensions and finishes. In electronics, very dry air increases static concerns on moisture-responsive materials. In produce storage and mushroom growing, evaporation can affect sellable weight while cold surfaces remain vulnerable to condensation. Compare measurable outcomes such as scrap, downtime and moisture loss when building a business case.
What can 25 lb/h of evaporation do? At ordinary room conditions, evaporating one pound of water absorbs roughly 1,050 BTU of sensible heat. A fully evaporated 25 lb/h stream therefore represents about 26,000 BTU/h of sensible cooling, or about 2.2 refrigeration tons. This is the thermal effect in the treated air. Useful cooling at the product depends on ventilation, wet bulb, heat loads and allowable RH.
What maintenance should be quoted? Specify who changes water-treatment consumables, checks the humidistat, inspects drain points and verifies operation after a seasonal shutdown. A dry idle condition can reduce standing-water concerns, but review the actual piping, filters and storage equipment included in the installation. For steam equipment, include the heat exchanger or steam generator, cylinder or scale service, and distribution losses where applicable.
Industrial humidifier sizing and performance questions
How do I compare steam and fog at the same output?
Compare pounds of water actually evaporated per hour, then add the electrical and thermal inputs for each industrial humidification system. Smart Fog’s published example uses approximately 0.4 kW at 25 lb/h based on average compressed-air use, compared with approximately 8 kW for electric steam at similar output. Check that example against the site compressor’s measured specific power, the proposed water-treatment system and any HVAC reheat. The estimate is an equipment comparison, not a forecast of annual facility savings.
Can an industrial humidifier reduce cooling demand?
Yes, when the space needs moisture and can use the cooling effect. Adiabatic humidifiers evaporate water directly into moving air, lowering its dry-bulb temperature while increasing relative humidity. At 95°F dry bulb and 70°F wet bulb, a system operating at 80% evaporative effectiveness would cool that airstream by 20°F. In humid weather the same industrial humidification system has less cooling potential. Compare direct and indirect evaporative cooling.
What does automatic humidity control measure?
A humidistat measures air humidity and signals the system to add moisture when the space falls below the selected band. Smart Fog reports that its adiabatic systems can maintain approximately ±1–2% RH in suitable applications. Document whether a quoted figure means relative-humidity percentage points at one sensor, sensor accuracy or uniformity throughout the space. These measures answer different questions.
Is humidification enough to prevent static damage?
Stable indoor humidity can reduce static charge accumulation on some materials, but sensitive electronics still require a qualified electrostatic discharge control program. Likewise, a humidifier can help stabilize paper and wood moisture content while storage, packaging and temperature still affect product quality. See how humidity fits into an ESD program.
Smart Fog system features
Smart Fog designs its systems around Self-Evaporating Droplets with a reported characteristic diameter of about 4.2 μm. The nozzle has no moving parts. System sizing, water treatment, air distribution and sensor placement determine how the installed system performs. Include available compressed air, electrical service and water quality in the proposal request.
Explore the droplet and control graphicsES100 direct spaceTS100 in ductES100M mobileMS100 custom grid