We’ll build your custom-designed greenhouse humidifier system according to your precise specifications.

Custom Design Greenhouse Humidifiers

The Smart Fog® System

Smart Fog® provides a series of custom-designed greenhouse humidifiers. Our greenhouse humidity control systems use Smart Fog® technology to produce self-evaporating droplets. The result is reliable humidity without condensation. Smart Fog greenhouse humidifiers offer enough capacity for greenhouses of all sizes.

MS100 Commercial Greenhouse Humidifiers

The MS100 greenhouse fogger system provides precise humidity control in spaces up to 10,000 square feet. The system functions as a free-standing humidifier for long-term placement but also offers portability and wall- or ceiling-mount capabilities. This greenhouse humidifier is a low-maintenance machine without moving parts. Its stainless steel nozzles prevent clogging and improve efficiency.

The MS100 humidification system for greenhouses includes a four-stage ZeroTDS® 1000 water filter system to eliminate high mineral content in its water supply. The system comes with a pipe and fittings kit.

Moreover, our MS100 humidifier system provides evaporative cooling and spraying to reduce the greenhouse’s temperature. The system works in temperature ranges of 50 degrees Fahrenheit or more. The greenhouse humidifiers reduce the temperature by up to 20 degrees Fahrenheit.

Each MS100 nozzle produces up to 1.5 gallons per hour of water. The greenhouse measures 6,912 square feet with a required 60% relative humidity level. Therefore, it comes down to a simple matter of math. The 20 MS100 units are required for proper environmental control.

Greenhouse Humidification Systems With Precise Controls

The MS100 system uses a CPLC2N controller, as well as an ES100PB1. The controllers set humidity and temperature with accurate automation capabilities. Additionally, our ES100PB1 includes a 2,400 liter per minute air filter set, a 130 mesh screen water filter and an air control electric valve.

Accurate, Responsive Humidity Sensors

Our greenhouse humidifier systems use an S1 relative humidity and temperature sensor that offers up to three years of accurate data collection and monitoring. The sensor triggers an INJ-1 injection system that releases moisture into the air when it detects humidity below the desired level. Since the INJ-1 injection system never requires priming, we apply the concentration ratio digitally into the controller.

request

Greenhouse Humidifiers Project Details

Product Description
Smart Fog® built an MS100 humidification system for a greenhouse.
Room Size 6,912 square feet
Relative Humidity Required 60 %
Characteristics Water Filtration

  • Used because Water Has High Mineral Content
Components Used
  • MS100 x 20 pcs
  • CPLC2N Control
  • ES100PB1
  • INJ Injection System
  • S1 Relative Humidity & Temp Sensor
  • Zero TDS 1000 GPD Water Filter System
  • Pipe & Fittings Kit
Detailed Specifications Automatic monitoring of relative humidity level in the greenhouse. Customer requested to have a hook up to existing greenhouse humidifiers monitoring equipment. Additional Smart Fog® INJ-Injection system for spraying. The INJ-1 Smart Fog® injection system doesn’t require priming, and you can enter the concentration ratio digitally into the controller.
CPLC Controller Program included in this solution: Smart Fog® injector program included.ES100PB1 Includes: 2400 L/min air filter set, 130 mesh screen water filter and air control electric valveRelative Humidity Range: 0 to 100% RH
Temperature Range: -40 to 140°F (-40 to 60°C)
Accuracy, RH: ±1 %
Accuracy, Temp Models with 4-20mA Temp. Output: ±0.9°F @ 72°F (±0.3°C @ 25°C)
Accuracy, Temp Models with Passive Thermistor Temp Sensor: ±0.4°F @ 77°F (±0.22°C @ 25°C)
Hysteresis, RH: ±1%
Repeatability, RH: ±0.1% typical

Temperature Limits: -40 to 140°F (-40 to 60°C)
Storage Temperature: -40 to 176°F (-40 to 80°C)
Compensated Temperature Range, RH: -4 to 140°F (-20 to 60°C)

4-20 mA Loop Powered Models:
Power Requirements: 10-35 VDC
Output Signal: 4-20 mA

0-10 V Output Models:
Power Requirements: 15-35 VDC or 15 –29 VAC
Output Signal: 0-10 V @ 5 mA max

0-5 V Output Models:
Power Requirements: 10-35 VDC or 10–29 VAC.
Output Signal: 0-5 V @ 5 mA max

Response Time: 15 seconds

Electrical Connections: Removable screw terminal block
Drift: <1% RH/year
RH Sensor: Capacitance polymer
Temperature Sensor: 4-20 mA Output, Solid State Band Gap. Passive

Output: 10K @ 25°C Thermistor (Dwyer curve A)
Enclosure: ABS

Enclosure Rating: Designed to meet NEMA 3S (IP54)
Weight: 0.3 oz (8.5 g)
Agency Approvals: CE

Industry of Use Greenhouse
Location Texas
Application Name Greenhouse Humidification System

applications btn

Custom Design Greenhouse Humidifier System

Your application is unique, so trust Smart Fog for a custom greenhouse humidifier solution. After a brief consultation, we’ll design the system and get it up and running at your facility. We integrate our humidification system into existing greenhouse monitoring equipment. Our MS100 units automatically monitor the relative humidity level in the greenhouse. The high mineral content in the water quickly vanishes, fulfilling all our client’s specifications.

Request a Quote

For more information on our greenhouse humidifiers, please contact Smart Fog® today. Request a free quote or get details on our full design and equipment services.